Reference: ODL24082701
Air9000P DC Power Analyzer is a small handheld high-precision power consumption tester precise, reliable comparable to Keysight N6705C, and also functions as a power source.
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
The Air9000P is a fully functional, stable, and reliable small handheld high-precision power consumption analyzer that supports PC-side software.
Powered through a USB-C interface for measuring the voltage and current of low-power devices.
Suitable for battery-powered products, supporting specified voltage output (0~5V).
Supports current limiting output, allowing for setting any current limiting value within the range of 0~2A.
The current measurement range of 0~2A with a measurement accuracy of ±0.1% ±3 digits and a minimum resolution of 0.1μA.
Voltage measurement range of 0~5V with a measurement accuracy of ±0.1% ±3 digits and a minimum resolution of 1mV.
OCP overcurrent protection automatically limits the current output to below 1.5A in case of a circuit short-circuit.
Multiple-channel synchronous current sampling with no shift delay, a sampling rate of up to 10KHz to meet low-power testing requirements.
Connectable to PC-side software for viewing and analyzing current waveforms, catering to power consumption testing needs of cellular modules, Bluetooth chips, Wi-Fi chips, etc.
Command-line tools are available for capturing serial port data on any device (Win/Linux/Mac) and importing it for viewing using PC-side software.
Voltage output: 0~5V
Adjustable voltage: 1mV
Current limit: 0~2A
Adjustable current: 0.1μA
Maximum power: 10W
Power supply mode: 4.5V~5.5V
Voltage Range: 05V
Voltage Accuracy: 1mV
Current Range: 02A
Current Accuracy: 0.1μA
Maximum Power: 10W
Power Supply: USB-C/5V
Hardware Sampling Rate: 100KHz
Host Computer Sampling Rate: 10KHz
Host Computer Software: Windows 7 and above
API Interface: Open dynamic library API interface
Maximum measurement ranges Maximum voltage of 5V with a minimum resolution of 1mV; maximum current of 2A with a minimum resolution of 0.1μA.
Maximum measurement accuracy: Utilizes a high-precision reference chip, 12-bit ADC design, and default factory calibration, with accuracy up to ±0.1% ±3 digits.
Current measurement range: Current display ranges of 200μA, 20mA, and 2A, automatically switching based on the current being tested.
Gear switching speed: Air9000P employs multi-channel synchronous sampling with no gear shifting delay.
Voltage drop switching speed: Air9000P uses 2/3 channel sampling resistors with a maximum delay of 100μs when the sampling resistor is shorted.
Current measurement accuracy: Resolution of 0.1μA in the 200μA range, 10μA in the 20mA range, and more data can be found in the table below.
| Type | Range | Resolution | Actual Accuracy | Note |
| Voltage setting | 0V-5V | 1mV | ± 0.1% ± 3 digits | |
| Voltage Read-Back | 0V-5V | 10mV | ± 0.1% ± 3 digits | |
| Current setting | 0-2A | 1μA | ± 0.1% ± 3 digits | |
| 200μA | 0.1μA-200μA | 0.1μA | ± 0.1% ± 3 digits | Automatic range |
| 20mA | 200μA-20mA | 10μA | ± 0.1% ± 3 digits | Automatic range |
| 2A | 20mA-2A | 1mA | ± 0.1% ± 3 digits | Automatic range |
1x Air9000P
1x USB-A2C cable
2x Alligator clips
Your review appreciation cannot be sent
Report comment
Report sent
Your report cannot be sent
Write your review
Review sent
Your review cannot be sent
Reference: ODL24082701
Reference: ODL24082705
Reference: ODL22082202
Reference: ODL22082201
Reference: ODL22082507
Reference: ODL25041502
Reference: DWM22051601
Reference: ODL25022601
Air9000P DC Power Analyzer is a small handheld high-precision power consumption tester precise, reliable comparable to Keysight N6705C, and also functions as a power source.
check_circle
check_circle